Setting up a Node with a Single NIC¶
Installing the STN Daemon¶
The STN (Steal the NIC) daemon must be installed on every node in the cluster that has only one NIC. The STN daemon installation(*) should be performed before deployment of the Contiv-VPP plugin.
* Docker daemon must be present when installing STN. Also, Docker must be configured to allow shared mount. On CentOS, this may not be the case by default. You can enable it by following the instructions at https://docs.portworx.com/knowledgebase/shared-mount-propagation.html.
Run as root (not using sudo):
bash <(curl -s https://raw.githubusercontent.com/contiv/vpp/master/k8s/stn-install.sh)
The install script should output the following:
Installing Contiv STN daemon.
Starting contiv-stn Docker container:
550334308f85f05b2690f5cfb5dd945bd9c501ab9d074231f15c14d7098ef212
Check that the STN daemon is running:
docker ps -a
CONTAINER ID IMAGE COMMAND CREATED STATUS PORTS NAMES
550334308f85 contivvpp/stn "/stn" 33 seconds ago Up 33 seconds contiv-stn
Check that the STN daemon is operational:
docker logs contiv-stn
The expected logs would look like the following excerpt:
2018/02/23 10:08:34 Starting the STN GRPC server at port 50051
For more details, please read the Go documentation for contiv-stn and contiv-init.
Creating a VPP Interface Configuration¶
Create the VPP configuration for the hardware interface as described here.
Configuring STN in Contiv-VPP K8s Deployment Files¶
The STN feature is disabled by default. It needs to be enabled either globally, or individually for every node in the cluster.
Global Configuration:¶
Global configuration is used in homogeneous environments where all nodes in
a given cluster have the same hardware configuration, for example only a single
Network Adapter. To enable the STN feature globally, put the StealFirstNIC: True
stanza into the [contiv-vpp.yaml
][1] deployment file, for example:
data:
contiv.yaml: |-
TCPstackDisabled: true
...
StealFirstNIC: True
...
IPAMConfig:
Setting StealFirstNIC
to True
will tell the STN Daemon on every node in the
cluster to steal the first NIC from the kernel and assign it to VPP. Note that
the Network Adapters on different nodes do not need to be of the same type. You
still need to create the respective vswitch configurations on every node in the
cluster, as shown [above](#creating-a-vpp-interface-configuration).
Individual Configuration:¶
Individual configuration is used in heterogeneous environments where each node
in a given cluster may be configured differently. To enable the STN feature
for a specific node in the cluster, put the following stanza into its Node
Configuration in the [contiv-vpp.yaml
][1] deployment file, for example:
...
NodeConfig:
- NodeName: "ubuntu-1"
StealInterface: "enp0s8"
- NodeName: "ubuntu-2"
StealInterface: "enp0s8"
...
Note that you still have to create the vswitch configuration on the node as shown here.
Uninstalling the STN Daemon¶
Run as root (not using sudo):
bash <(curl -s https://raw.githubusercontent.com/contiv/vpp/master/k8s/stn-install.sh) --uninstall
The install script should output the following:
Uninstalling Contiv STN daemon.
Stopping contiv-stn Docker container:
contiv-stn
contiv-stn
contiv-stn
Make sure that the STN daemon has been uninstalled:
docker ps -q -f name=contiv-stn
No containers should be listed.